Program *03 for DK424 – Cabinet Type Identification

Program *03 for DK424 – Cabinet Type Identification

Processor Type: RCTUE/F or B5CAU/B5CBU

Program Type: System

Initialized Default: All cabinets = 1

￿ ￿￿ ￿ ￿￿￿￿ ￿ 6SNU ￿￿ ￿ +ROG ￿ 6SNU Initialized Default: All cabinets = 1Program *03 - Overview

SELECT = Cabinet No. (1~7) 3-12

CABINET = 1 or 2 (type)

Type 1 (DK424 or DK424i)

Type 2 (DK280)

Manual backgroundManual background +ROG ￿ 6SNU ￿ ￿ +ROG ￿ 6SNU ￿ ￿ +ROG ￿

Turn System Power Off (5 sec) then On.

or...

Run Program 91-2

 

SELECT =

Cabinet Type

 

(Cabinet No. 1~7)

(1 or 2)

 

 

 

1

(Base)

 

 

 

 

2

(1st Expansion)

 

 

 

 

3

(2nd Expansion)

 

 

 

 

4

(3rd Expansion)

 

 

 

 

5

(4th Expansion)

 

 

 

 

6

(5th Expansion)

 

 

 

 

7

(6th Expansion)

1 only

 

 

 

Expansion Cabinet Universal PCB Slot Availability

Case 1

RCTUE/F in DK424 Base Cabinet with MBJU removed

Expansion Cabinet (max 6)

Universal PCB Slots

DK424

1~8 available

 

 

DK280

1~6 available

 

 

Note MBJU is not used with DK424i cabinets.

Case 2

RCTUE/F in DK280 Base Cabinet

Expansion Cabinet (max 5)

Universal PCB Slots

DK424

1~6 available

 

 

DK280

1~6 available

 

 

Program *03 - Overview

You must run this program when using the DK424 or DK280 RCTUE/F, or DK424i B5CAU/BU. It identifies which type of cabinets are installed (DK424i, DK424 or DK280).

The RCTUE/F processor can be installed in a DK424 or DK280 base cabinet. The expansion cabinets can be any combination of DK424 and DK280 - except the seventh expansion cabinet must be a DK424.

The DK280 expansion cabinet can only support six universal PCB slots in any possible configuration.

The DK424 expansion cabinet supports eight universal PCB slots only if the RCTUE/F is installed in a DK424 base cabinet and the MBJU jumper is removed from the DK424 base cabinet backplane. MBJU does not apply with DK424i cabinets.

Important! This programs exists on DK424i B5CAU/BU processors. It must always be set to Cabinet Type “1” allowing 10 slots for each DK424i Expansion Cabinet. DK280 and DK424 Expansion Cabinets cannot be used with DK424i processors.