Toshiba DK40I Programs 46-11~46-81Overview, 4-36, Toll Restriction, Processor Type, Program Type

Models: DK40I dk14

1 424
Download 424 pages 49.24 Kb
Page 270
Image 270
Initialized Default: Leaves all LEDs Off

Toll Restriction

Programs 46-11~46-81 – Toll Restriction Class (1~8) Parameters

Programs 46-11~46-81 – Toll Restriction Class (1~8) Parameters

 

 

 

Processor Type:

 

DK14, DK40i, all RCTUs and BCUs

 

 

 

Program Type:

 

Toll Restriction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Initialized Default: Leaves all LEDs Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿

￿￿

￿

￿￿

￿￿

￿

6SNU

￿

￿

+ROG

￿

6SNU

 

 

 

 

￿

 

 

 

+ROG

￿

6SNU

￿

￿

+ROG

￿

6SNU

￿

￿

+ROG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Select Class from Legend below.

 

 

 

 

 

 

 

 

 

 

Light LED Buttons as required to assign Table to Class.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Processor

Toll Restriction Class

Exception Table

DK14

1~4

8

 

 

 

DK40i

1~4

8

 

 

 

RCTUA

1~4

8

 

 

 

Processor

Toll Restriction Class

Exception Table

RCTUBA/BB, B1CU

1~4

8

 

 

 

RCTUC/D, B2CAU/BU, B3CAU/BU

1~8

16

 

 

 

RCTUE/F, B5CAU/BU

1~8

16

 

 

 

LED

 

X

LED On

LED Off

20~17

 

Not Used

 

 

 

 

 

 

16

 

 

Table 16 Area/Office Exception

Not Selected

 

 

 

 

 

15

 

 

Table 15 Area/Office Exception

Not Selected

 

 

 

 

 

14

 

 

Table 14 Area/Office Exception

Not Selected

 

 

 

 

 

13

 

 

Table 13 Area/Office Exception

Not Selected

 

 

 

 

 

12

 

 

Table 12 Area/Office Exception

Not Selected

 

 

 

 

 

11

 

 

Table 11 Area/Office Exception

Not Selected

 

 

 

 

 

10

 

 

Table 10 Area/Office Exception

Not Selected

 

 

 

 

 

9

 

 

Table 09 Area/Office Exception

Not Selected

 

 

 

 

 

8

 

 

Table 08 Area/Office Exception

Not Selected

 

 

 

 

 

7

 

 

Table 07 Area/Office Exception

Not Selected

 

 

 

 

 

6

 

 

Table 06 Area/Office Exception

Not Selected

 

 

 

 

 

5

 

 

Table 05 Area/Office Exception

Not Selected

 

 

 

 

 

4

 

 

Table 04 Area/Office Exception

Not Selected

 

 

 

 

 

3

 

 

Table 03 Area/Office Exception

Not Selected

 

 

 

 

 

2

 

 

Table 02 Area/Office Exception

Not Selected

 

 

 

 

 

1

 

 

Table 01 Area/Office Exception

Not Selected

 

 

 

 

 

Programs 46-11~46-81 Overview

Run these programs for area/office code exception table assignments.

Refer to the legend above the record sheet for exception tables and classes. Exception tables for both area and office codes will be defined in Program 47. Each class can be assigned any or all of the available office code exception tables.

4-36

Strata DK Programming 5/00

Page 270
Image 270
Toshiba DK40I, dk14, DK424I manual Programs 46-11~46-81Overview, 4-36, Toll Restriction, Processor Type, Program Type