Toshiba DK424, dk14 Program 34 – Hold Recall Timing, Program 34 Overview, 3-97, System & Station

Models: DK40I dk14

1 424
Download 424 pages 49.24 Kb
Page 141
Image 141
Program 34 – Hold Recall Timing

System & Station

Program 34 – Hold Recall Timing

Program 34 – Hold Recall Timing

Processor Type: DK14, DK40i, all RCTUs and BCUs

Program Type: Station

Initialized Default: Assigns a Hold Recall Time of 032 seconds to all ports

￿ ￿￿ ￿ ￿￿￿￿ ￿ 6SNU ￿ ￿ +ROG ￿ 6SNU Program 34 Overview3-97Manual background

SELECT = Station Logical Port Number Manual background

Manual backgroundManual background ￿ Manual backgroundManual background

Manual backgroundManual background +ROG ￿ 6SNU ￿ ￿ +ROG ￿ 6SNU ￿ ￿ +ROG

HOLD TIME = Seconds

Enter the port number having its Hold

Recall Time defined.

To add a port range, enter XXXXXX (low port high port).

Processor Type

Port Range

DK14

000~009

 

 

DK40i

000~027

 

 

RCTUA

000~031

 

 

RCTUBA/BB

000~079

 

 

RCTUC/D

000~239

 

 

RCTUE/F

000~335

 

 

Port

Seconds

Port

Seconds

Enter the number of seconds the system will wait (three digits).

Enter 000 for no Hold Recall. Enter 011~160 for 11 to 160 seconds.

Processor Type

Port Range

B1CU

000~055

 

 

B2CAU/BU

000~111

 

 

B3CAU/BU

000~191

 

 

B5CAU/BU

000~335

 

 

Port

Seconds

Port

Seconds

System & Station

Program 34 Overview

Each station can have a different time (from 011 to 160 seconds) from the point of placing a call on hold to the point of recall. Initialized data assigns a recall time of 032 seconds to all ports.

Strata DK Programming 5/00