When the Recorded Image is not Clear... - continued

Recording Unit Cleaning Procedure - continued

11 Clean the Metering Blade

Return the Charger

12 Cleaner and Mylar

Scraper

13 Clean the Mylar Sheet

Attach the Drum

14 Unit to the Developer Assembly

Return the Developer

15 Assembly (with Drum Unit)

and Close the Top Cover

Metering

Blade

Mylar

Scraper

090Toner Roller

When a white line occurs on the black toner roller of Devel- oper Assembly, scrape off the dust or toner between the me- tering blade and black toner roller with a Mylar Scraper.

Charger Cleaner

Mylar

Scraper

028

Return the Charger Cleaner and Mylar Scraper to the storage lo- cation provided inside the fac- simile.

Cotton

Swab

Mylar Sheet

092

Clean the mylar sheet of the Developer Assembly with a cot- ton swab.

 

Drum Unit

 

Developer

042

Assembly

Attach the Drum Unit to the Developer Assembly.

Position the Drum Unit with the green drum surface facing the black toner roller on the Devel- oper Assembly.

045

Install the Developer Assem- bly (with the Drum Unit at- tached) and close the Top Cover.

When the Top Cover is closed, the unit automati- cally returns to the Standby Mode.

239

Page 241
Image 241
Toshiba DP125F, Dp120F manual 239