Drum Unit Replacement - continued

Attach the new Drum

4 Unit to the Developer Assembly

Install the Developer

 

6 Press Down on the

5 Assembly with Drum

 

Unit

 

Drum Unit

 

 

 

 

 

Replacing the Ozone Filter

The Ozone Filter should be re- placed every time the Drum Unit is replaced.

7 Replace the Ozone Filter

 

Drum Unit

 

Developer

042

Assembly

Attach the new Drum Unit to the Developer Assembly. Position the new Drum Unit with the green drum surface facing the black toner roller on the Devel- oper Assembly.

Developer

Assembly

043

Holding the Developer Assem- bly by the green handles, align the three shafts on the Devel- oper Assembly sides with the slots in the machine frame.

Drum Unit

044

Press firmly down on the green squares on the Drum Unit until the Drum Unit clicks into place.

A new Ozone Filter has been provided with the Drum Kit. Make sure the Ozone Filter is replaced.

Ozone Filter

069

Remove the Ozone Filter from the inside of the machine. Then, place the new Ozone Fil- ter into the machine.