1.11 Measurement of Transfer Guide Bias

The transfer charger bias is applied to the pinch roller and the paper guide plate to prevent the transfer charger charge from escaping through the recording paper during transfer. To analyze the cause of a transfer failure which has occurred, you can output the transfer guide bias in the output test at any time and then measure the voltage.

Important:

Measure the transfer guide bias with the toner cartridge and the process unit taken out from the copier and the front cover open. Also, keep the front cover switch and interlock switch (front cover) ON by using the switch jigs (big/small).

<Keys used in operation>

1

 

3

 

 

 

Power ON

10.OUTPUT TEST

SET

2 5 0

SET

START

CANCEL

2

5

5

<Display messages and measurement methods >

FUNCTION TEST

09.CODEC TEST

10.OUTPUT TEST 11.PRINTER BOARD TEST

: Enter the "Developer Bias Transformer ON/OFF" code. Important:

Before outputting the transfer guide bias, it is necessary to turn the developer bias ON.

: Developer bias ON Warning:

High voltage is output from the developer bias terminal. NEVER touch the terminal while measuring.

Developer bias measuring plate

01-11-01

: Enter the "Transfer Guide Bias ON/OFF" code.

SET

To next page

e-STUDIO160/200/250 ADJUSTMENT

1 - 92