b) Secondary scanning reproduction ratio

(1) Place the scale (horizontal to the copy movement direction) and make an A3/LD 100% copy.

Copied scale

Copy movement direction

Actual scale

01-04-09

(2)Compare the copy and the scale.

(3)In order to adjust the divisions of the scale, do as follows.

0

 

5

 

 

 

Power ON

3

0

4

SET

Digital Keys

SET

INT

START

INT

Power OFF

(Code)

or

(Set the value)

or

 

(Test copy)

 

 

 

 

 

START

 

START

 

 

 

 

Notes: 1. An increase in the value corresponds to an increase in the division of scale (0.1 %/step).

2.Adjustment value is able to be input within the range of 0 - 255. The default adjustment value is 128.

e-STUDIO160/200/250 ADJUSTMENT ITEMS

1 - 62

December 2002 TOSHIBA TEC

Page 70
Image 70
Toshiba e-Studio200, e-Studio250, e-Studio160 manual Copied scale Copy movement direction Actual scale