5. UPDATING THE FIRMWARE
5.1 Outline
When you want to use the latest version of the firmware, or when the firmware is damaged and the copier is inoperable, the following procedure is used to update the firmware.
The firmware contains two types of data: Main Data (program data/function data/language data) stored in the flash ROM on the main PWA, and Scanner Data stored in the flash ROM on the scanner control PWA. The updating procedures vary with the data types. For details, refer to each procedure.
Important: • Before updating, be sure to print “FUNCTION LIST.” In case the updating fails for some reason disabling this machine from operating, set the functions by checking with this list and then restore the machine.
•If updating is performed with the FAX kit
Downloading data from the recovery PWA.
Refer to 5.2 Using the recovery PWA (on page
Using the batch file of the
Refer to 5.3 Using the batch file (on page
Using the TOSHIBA Viewer, downloading data from the PC.
Refer to 5.4 Using the TOSHIBA Viewer (on page
Using the RDC (Remote Diagnosis Configuration), downloading data.
*The Refer to the RDC Manual.
Note: The version of the firmware currently installed can be confirmed in the “FUNCTION LIST (In SERVICE MODE).”