(10) Uneven image density

Feeding direction

Step

Cause/Defect area

Check items

Measures

 

 

 

 

1

Paper

Paper in cassette or LCF damp?

Change paper.

 

 

 

Avoid storing paper in damp place.

 

 

 

 

2

Laser scanner unit

Foreign matter or dust on lens?

Remove foreign matter or dust with blower.

 

 

 

(Do not use a cloth.)

 

 

 

 

3

Process unit

Main charger wire stained?

Clean charger wire.

 

(main charger)

 

 

 

 

 

 

4

Process unit (developer)

Is toner put in process unit in an

Shake process unit horizontally to place toner

 

 

unbalanced manner?

evenly.

 

 

 

 

5

Transfer charger unit

Transfer charger unit securely in-

Re-install transfer charger unit securely.

 

 

stalled?

 

 

 

 

 

6

 

Transfer charger wire dirty?

Clean transfer charger wire.

 

 

 

 

7

 

If problem persists after measures

Replace process unit, transfer charger unit,

 

 

are applied, or there is no prob-

or laser scanner unit.

 

 

lem found in above check, follow

 

 

 

procedure described in right col-

 

 

 

umn.

 

 

 

 

 

e-STUDIO160/200/250 TROUBLESHOOTING