b) Laser starting position 600 dpi/PPC
(1) Make a test print and adjustment as in the following procedure.
0 | 5 |
|
|
|
|
|
|
|
|
|
Power ON | INTERRUPT |
| PROGRAM | * # * | * | 05:TEST MODE | SET | |||
|
|
|
|
|
|
|
|
| ||
|
| After 3 sec. | Enter SERVICE MODE |
|
|
| ||||
|
| 04:FUNCTION TEST | SET | 02:PRINT TEST | SET | 1 | 4 2 | |||
|
|
|
|
|
|
|
|
| (Code) | |
|
| SET | Digital Keys | SET | START | C/S | OK | Power OFF | ||
|
|
| (Cassette) |
|
| (Print end) |
|
| ||
|
|
|
|
|
|
|
| NG |
|
|
|
| MAIN MENU | INTERRUPT | Digital Keys | SET | Digital Keys | SET | |||
|
|
|
|
|
| (Code) | or | (Set the value) | or | |
|
|
|
|
|
|
| START |
|
| START |
(2) Measure the distance "B" which is the distance from the left side of the test print paper to the 6th line.
Print movement direction
6
B
(3) In order to set the distance "B" to 50 mm.
Notes: 1. An increase in the value makes the distance B longer.
2.The adjustment is made for each paper cassette. Paper cassette selection values (1) and cor- responding codes (3) in paper cassette adjustment.
3.Adjustment value is able to be input within the range of 0 - 255.
Paper cassette | Cassette selection value | Code | Default | Step |
|
|
|
|
|
Cassette 1 | 1 | 410 | 108 |
|
|
|
|
|
|
Cassette 2 | 2 | 417 | 106 |
|
|
|
|
|
|
Cassette 3/LCF | 3 | 418 | 119 | 0.043 mm |
|
|
|
|
|
Cassette 4 | 4 | 419 | 128 |
|
|
|
|
|
|
Bypass | 0 | 497 | 101 |
|
|
|
|
|
|
December 2002 TOSHIBA TEC | 1 - 57 |