CCA

Lower stack tray lift motor is abnormal

Is the wiring between the finisher controller PWA and lower stack tray lift motor correct?

NO

YES

Correct the wiring.

Are the front and rear sides of the lower stack tray leveled?

NO

YES

Level them.

Is the lower stack tray lift motor clock sensor working properly?

NO

YES

Replace the sensor.

Is the stack tray paper height sensor working properly.

NO

YES

Replace the sensor.

Are the lower stack tray upper limit sensor and lower stack tray lower limit sensor working properly?

NO

YES

Replace the sensor or sensor controller PWA.

Does the voltage between the pins J3-1 and -2 on the finisher controller PWA become 24V when the lower stack tray lift motor starts rotating?

NO

YES

Replace the finisher controller PWA.

Check the wiring between the upper stack lift motor and finisher controller PWA. If there is no problem, replace the lower stack tray lift motor.

December 2002 TOSHIBA TEC

4 - 53

e-STUDIO160/200/250 TROUBLESHOOTING

Page 175