(3) In order to set the distance "D" to 50 mm.

Notes: 1. An increase in the value increases the distance "D" (0.4 mm/step).

2.Adjustment value is able to be input within the range of 0 - 15. Default adjustment value is 8. In case of the cassette 1 feeding (Code "440"), adjustment value is within the range of 0 - 40 (Default adjustment value is 23).

3.Since the cassette 1 adjustment value becomes a standard for all adjustments, this adjustment must always be performed in the order stated above.

4.The adjustment is made for each paper cassette. Paper cassette selection values (1) and cor- responding codes (3) in paper cassette adjustment.

Paper cassette

Cassette selection value

Code

 

 

 

Cassette 1

1

440

 

 

 

Cassette 2

2

441

 

 

 

Cassette 3/4

3/4

444

 

 

 

Bypass

0

442

 

 

 

LCF

3

443

 

 

 

5.To confirm the adjustment of ADU (code 445), do not print a test print in the procedure in (1), but copy the TEST CHART.