(3) In order to set the distance "D" to 50 mm.
Notes: 1. An increase in the value increases the distance "D" (0.4 mm/step).
2.Adjustment value is able to be input within the range of 0 - 15. Default adjustment value is 8. In case of the cassette 1 feeding (Code "440"), adjustment value is within the range of 0 - 40 (Default adjustment value is 23).
3.Since the cassette 1 adjustment value becomes a standard for all adjustments, this adjustment must always be performed in the order stated above.
4.The adjustment is made for each paper cassette. Paper cassette selection values (1) and cor- responding codes (3) in paper cassette adjustment.
Paper cassette | Cassette selection value | Code |
|
|
|
Cassette 1 | 1 | 440 |
|
|
|
Cassette 2 | 2 | 441 |
|
|
|
Cassette 3/4 | 3/4 | 444 |
|
|
|
Bypass | 0 | 442 |
|
|
|
LCF | 3 | 443 |
|
|
|
5.To confirm the adjustment of ADU (code 445), do not print a test print in the procedure in (1), but copy the TEST CHART.
1 - 60 | December 2002 TOSHIBA TEC |