043-6
Fig. 1-8-4

(c) Image skewing adjustment

 

After installing scanner unit, hold the document to

 

the ADF glass and make a copy. Check the image

 

for tilt. If tilt has occurred, make adjustments in the

 

following manner:

Screw

Screw

1.If an Original Cover (KA-1600PC), ADF (MR- 2012), or the RADF (MR-3011) is attached to

the copier, detach it.

2. If a STP (KK-1600) is attached to the copier, disconnect the power cable.

3.Detach the manual pocket.

4.Detach top cover.

(See Fig. 2-6-2 of the Service Manual)

5.Loosen 6 screws retaining original glass.

6.If the tilt is as shown below, loosen 6 screws retaining stopper, move (adjust) original glass stopper plate to the front side, and then secure it.

 

Tab

Stopper

 

 

 

Original glass

 

043-7-1

 

043-7-2

 

 

Fig. 1-8-5

7.If the tilt is as shown below, loosen 6 screws retaining stopper, move (adjust) original glass stopper plate to the rear side, and then secure it.

 

Stopper

 

Tab

 

Original glass

043-8-1

043-8-2

 

 

Fig. 1-8-6

December 2002 TOSHIBA TEC

1 - 75

e-STUDIO160/200/250 ADJUSTMENT ITEMS

Page 83
Image 83
Toshiba e-Studio160, e-Studio250, e-Studio200 manual Tab Stopper Original glass