1.8 Adjusting the Scanner Section

1.8.1Installing glass

(a) Installing ADF glass

To install new ADF glass, wipe off the mounting surface and mount the glass by placing it at the position shown right.

(b) Installing original glass

Original glass should be installed in the following manner:

1.Place the ADF glass by aligning with the posi- tioning tab.

2.Hold original glass to the stopper and tighten 4 screws.

3.Hold original glass stay to original glass and tighten 2 screws.

043-3

ADF glass

Fig. 1-8-1

Stopper

Tab

Original

glass

043-4

Fig. 1-8-2

Screw

Original glass stay

Original glass

Screw

043-5

Fig. 1-8-3

e-STUDIO160/200/250 ADJUSTMENT ITEMS

1 - 74

December 2002 TOSHIBA TEC

Page 82
Image 82
Toshiba e-Studio200, e-Studio250, e-Studio160 manual Adjusting the Scanner Section