Classification

Error code

Machine status

 

 

 

CALL SERVICE from the

C21

Carriage initialization error

 

 

 

optical system

C22 to C24

Reserved

 

 

 

 

C25

Scanner unit watch dog error

 

 

 

 

C26

Exposure lamp disconnection or peak detection error

 

 

 

 

C27 to C30

Reserved

 

 

 

CALL SERVICE from the

C31 to C37

Reserved

 

 

 

process system

C38

Replaced process unit error

 

 

 

 

C39 to C40

Reserved

 

 

 

CALL SERVICE from fuser

C41

Abnormal thermistor or heater disconnection at power ON

 

 

 

area

C42

Reserved

 

 

 

 

C43

Warming up mode after disconnection judgment, or ab-

 

 

normal thermistor after ready

 

 

 

 

C44

Warming up mode after disconnection judgment, or heater

 

 

abnormal after ready

 

 

 

 

C45

Thermistor disconnection at the end part of heater

 

 

 

 

C46 to C50

Reserved

 

 

 

CALL SERVICE from commu-

C51 to C55

Reserved

 

 

 

nication

C56

Communication error between PFC and main unit

 

 

 

 

C57

Communication error between main unit and IPC

 

 

(e-STUDIO200/250 series)

 

 

 

 

C58

Communication error between IPC and finisher

 

 

(e-STUDIO200/250 series)

 

 

 

 

C59 to C70

Reserved

 

 

 

CALL SERVICE from ADF or

C71

Paper supply motor lock error

 

 

 

RADF

C72

Reserved

 

 

 

 

C73

EE-PROM initialization error

 

 

 

 

C74

Defective adjustment by the exit/reversal sensor detected

 

 

 

 

C75 to C80

Reserved

 

 

 

 

C81

Fan motor lock error

 

 

 

 

C82

Document aligning lower sensor (RADF)/Aligning sensor

 

 

(ADF) adjustment error

 

 

 

 

C83

Size length adjustment error

 

 

 

 

C84 to C89

Reserved

 

 

 

e-STUDIO160/200/250 ADJUSTMENT ITEMS

1 - 4

December 2002 TOSHIBA TEC

Page 12
Image 12
Toshiba e-Studio250, e-Studio200, e-Studio160 manual Radf