1.3 Image Quality Control
If the user wants to change the image density, adjust the image density in adjust mode "05."
| Original mode |
| Adjustment item | Remarks | |||
|
|
|
|
|
|
| |
| Photo/Text | Photo |
| Text |
|
|
|
|
|
|
|
|
|
|
|
| 503 | 501 |
| 504 | Standard PPC | Manual density | The larger the value, the darker |
|
|
|
|
|
| center value | the image |
|
|
|
|
|
|
|
|
| 505 | 506 |
| 507 | Light side | Manual density | The larger the value, the lighter |
Code |
|
|
|
|
|
| the light range |
|
|
|
|
|
|
| |
508 | 509 |
| 510 | Dark side | Manual density | The larger the value, the darker | |
|
| ||||||
|
|
|
|
|
|
| the dark range |
|
|
|
|
|
|
|
|
| 514 | 512 |
| 515 | Standard PPC | Automatic density | The larger the value, the darker |
|
|
|
|
|
|
| the image |
|
|
|
|
|
|
|
|
Follow the procedure below to adjust the image density to suit the user’s preferences while comparing the image obtained in the test copy and the currently entered allowable values.
<Keys used in operation> |
|
|
|
|
|
|
| ||
0 | 5 |
|
|
|
|
|
|
|
|
Power ON | Digital Keys | SET | Digital Keys | SET | INT | START | INT | Power OFF | |
| or |
| or |
|
|
|
| ||
|
| (Code) | (Set the value) |
| (Test print) |
|
| ||
|
|
|
|
|
|
| |||
|
|
| START |
| START |
|
|
|
|
Notes: 1. Adjustment value is able to be input within the range of 0 - 255. 2. Default values are as following.
Code | Default value |
|
|
501 | 139 |
|
|
503 | 133 |
|
|
504 | 130 |
|
|
505 | 28 |
|
|
506 | 18 |
|
|
507 | 20 |
|
|
508 | 13 |
|
|
509 | 20 |
|
|
510 | 18 |
|
|
512 | 140 |
|
|
514 | 133 |
|
|
515 | 130 |
|
|
December 2002 TOSHIBA TEC | 1 - 53 |