1.3 Image Quality Control

If the user wants to change the image density, adjust the image density in adjust mode "05."

 

Original mode

 

Adjustment item

Remarks

 

 

 

 

 

 

 

 

Photo/Text

Photo

 

Text

 

 

 

 

 

 

 

 

 

 

 

 

503

501

 

504

Standard PPC

Manual density

The larger the value, the darker

 

 

 

 

 

 

center value

the image

 

 

 

 

 

 

 

 

 

505

506

 

507

Light side

Manual density

The larger the value, the lighter

Code

 

 

 

 

 

 

the light range

 

 

 

 

 

 

 

508

509

 

510

Dark side

Manual density

The larger the value, the darker

 

 

 

 

 

 

 

 

 

the dark range

 

 

 

 

 

 

 

 

 

514

512

 

515

Standard PPC

Automatic density

The larger the value, the darker

 

 

 

 

 

 

 

the image

 

 

 

 

 

 

 

 

Follow the procedure below to adjust the image density to suit the user’s preferences while comparing the image obtained in the test copy and the currently entered allowable values.

<Keys used in operation>

 

 

 

 

 

 

 

0

5

 

 

 

 

 

 

 

 

Power ON

Digital Keys

SET

Digital Keys

SET

INT

START

INT

Power OFF

 

or

 

or

 

 

 

 

 

 

(Code)

(Set the value)

 

(Test print)

 

 

 

 

 

 

 

 

 

 

 

 

START

 

START

 

 

 

 

Notes: 1. Adjustment value is able to be input within the range of 0 - 255. 2. Default values are as following.

Code

Default value

 

 

501

139

 

 

503

133

 

 

504

130

 

 

505

28

 

 

506

18

 

 

507

20

 

 

508

13

 

 

509

20

 

 

510

18

 

 

512

140

 

 

514

133

 

 

515

130

 

 