(2)Operation Note

When adjusting the high-voltage output, a measuring jig is required. (except the developer bias measurement.)

Connect the digital testers as instructed in (1) and follow the procedure below to adjust the developer bias, main charger, transfer, separation output.

<Keys used in operation>

0

 

5

 

 

 

Power ON

Digital Keys : Enter code

<Display messages>

ADJUST MODE

MC =

SET

or

START

ADJUST MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MC

= XXX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: code No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DT

=

 

 

 

 

 

 

 

 

 

 

 

 

YYY

 

 

 

: Current entried adjustment value

 

 

Digital Keys

or

:Adjust value "YYY" so that the measurement values satisfy the values in the following table.

 

 

Developer

 

Main

 

Transfer Charger (On the drum)

 

 

Bias

Charger

 

 

 

 

 

 

 

 

 

 

 

High

 

Center

 

 

 

 

 

 

 

 

 

 

 

Code

205

210

 

 

220

 

221

 

 

 

 

 

 

 

 

 

 

 

 

e-STUDIO160

-430±5V

-637±5V

 

 

 

 

 

1098mV

Measurement

series

 

 

 

 

 

1372mV

 

±146mV

 

 

 

 

 

 

 

 

 

 

 

value

e-STUDIO200/

-460±5V

-674±5V

 

 

±191mV

 

1179mV

 

250 series

 

 

 

 

 

 

 

 

±193mV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Separation Charger (On the drum)

 

 

 

 

 

 

 

 

 

 

 

 

 

High

 

Center

 

Low

 

 

 

 

 

 

 

 

 

 

 

 

Code

233

 

234

 

 

235

 

 

 

 

 

 

 

 

 

 

 

 

Measurement

e-STUDIO160

-553mV

 

-425mV

 

-300mV

 

value

series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

e-STUDIO200/

±101mV

 

±51mV

 

±51mV

 

 

250 series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SET : Value "YYY" after adjustment is stored to SRAM. or

START

CANCEL

: Return to other adjustment mode.

Power OFF

e-STUDIO160/200/250 ADJUSTMENT

1 - 70

December 2002 TOSHIBA TEC

Page 78