RAM clear table
|
|
|
|
| Service parameter setting |
|
|
|
| |||
RAM data Country/ |
|
|
|
|
|
|
|
|
|
| ||
FUNC/ | Service | Service |
| Journal | Error data | Protocol | Counter | Drum |
| |||
|
| Region | adjustment |
| on FAX | related |
| |||||
RAM clear mode |
| setting | SYSFUNC/ | data ([0][5]) | setting data | report | communi- | trace | data | data |
| |
|
| UAD etc. | area | ([0][8]) area | data | cation | data | *a) | *b) |
| ||
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| Set default |
| Set default |
|
|
|
|
|
| |
[1] [3] [*] and turn ON | *2) *3) |
| value |
| value | *e) | Clear | Clear | Clear |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[1] [3] [#] and turn ON | *2) |
|
|
|
|
|
|
| Clear | Clear |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[*] [#] and turn ON | *2) |
|
|
|
|
| Clear | Clear | Clear |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
[START] [STOP] and |
|
| Set default |
| Set default |
|
|
|
|
|
| |
turn ON | *2) |
| value |
| value | *e) |
|
| Clear |
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| ||
[0] [8] and turn ON, then |
| Set default | Set default |
|
|
|
|
|
| |||
[6] [6] [5] | *1) |
|
| value | value |
|
|
| Clear |
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| Set default |
| Set default |
|
|
|
|
|
| |
[0] [2] and turn ON |
| Changeable | value |
| value | *e) | Clear | Clear | Clear |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. PIX MEMORY |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Set default |
|
|
|
|
|
|
|
|
|
2. EXCEPT USER MEMORY | value |
|
|
| Clear | Clear |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
3. ALL | *3) |
| Set default |
| Set default |
|
|
|
|
|
| |
(Same as “[1] [3] [*] and turn ON”) | value |
| value | *e) | Clear | Clear | Clear |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
4. USER AREA | *3) |
|
|
|
|
|
|
| Clear |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*1) In case of replacing the main board in the field, you can initializes the parameters related to copy function stored on the board using this function.
Therefore when this function is performed, it is necessary to readjust the follow- ing items.
1)Adjustment of paper aligning value
2)Printer unit adjustment
3)Scanner unit adjustment
4)ADF/RADF installation setting