C25

Scanner unit watch dog error

This error occurs when the watchdog register fails to be cleared within every certain time inter- val on the scanner control PWA (occurrence of a watchdog interrupt).

If C25 still occurs even after the power is turned off and then on, replace the scanner control PWA.

C26

Peak detection error

Does the lamp light up during initialization after the power is turned on?

NO (=The lamp does not light)

1. Check if the connector of the lamp is disconnected, or the harness is broken.

2.Check if the connector of the inverter is disconnected, or the harness is broken.

3.Check if any conductor pattern on the inverter and scanner control PWA is open- or short-circuited.

4.Replace the lamp.

5.Replace the inverter.

6.Replace the scanner control PWA.

7.Replace the relay PWA.

8.Replace the main PWA.

YES (=The lamp lights)

1.Check if the shading plate behind the document scale is dirty.

2.Check if the lens can be seen when looking the first carriage from the top.

3.Check if the optical system is extremely dirty or damaged.

4.Check if the FFC of the CCD PWA is disconnected.

5.Check if any conductor pattern on the CCD and scanner control PWA is open- or short- circuited.

6.Replace the CCD unit.

7.Replace the scanner control PWA.

8.Replace the relay PWA.

9.Replace the main PWA.

e-STUDIO160/200/250 TROUBLESHOOTING

4 - 40

December 2002 TOSHIBA TEC

Page 162
Image 162