C15 Abnormal operation of the 3rd tray in the PFP

Does the PFP tray (upper) move up? (using the test mode 10, Output Test, CODE 275)

NO

YES

1. Check if each connector between the PFP tray-up assembly (upper) and the PFP PWA (CN244) is disconnected.

2.Check if each connector between the PFP PWA (CN241, CN242) and the PFC PWA (CN206, CN207) is disconnected.

3.Check if each connector between the PFC PWA (CN201, CN202) and the relay PWA (CN35, CN36) is disconnected.

4.Check if each connector pin is removed or the harness is broken.

5.Check if any conductor pattern on the PFP, PFC, relay and main PWA is open- or short-circuited.

6.Replace the PFP tray-up motor of the PFP tray-up assembly (upper).

7.Replace the PFP PWA.

8.Replace the PFC PWA.

9.Replace the relay PWA.

10.Replace the main PWA.

Is the PFP pickup sensor working? (using the test mode 04, Sensor Test, DATA No. 17 Bit 0)

NO

YES

1. Check if each connector between the PFP pickup sensor and the PFP PWA (CN247) is disconnected.

2.Check if each connector between the PFP PWA (CN241) and the PFC PWA (CN206) is disconnected.

3.Check if each connector between the PFC PWA (CN201, CN202) and the relay PWA (CN35, CN36) is disconnected.

4.Check if the slit reaches the PFP pickup sensor.

5.Check if each connector pin is removed or the harness is broken.

6.Check if any conductor pattern on the PFP, PFC, relay and main PWA is open- or short-circuited.

7.Replace the PFP pickup sensor.

8.Replace the PFP PWA.

9.Replace the PFC PWA.

10.Replace the relay PWA. 11.Replace the main PWA.

1.Check if any conductor pattern on the PFC PWA is open- or short-circuited.

2.Replace the PFC PWA.

December 2002 TOSHIBA TEC

4 - 35

e-STUDIO160/200/250 TROUBLESHOOTING

Page 157
Image 157
Toshiba e-Studio200, e-Studio250, e-Studio160 manual Yes