CC9

Upper stack tray lift motor is abnormal

Is the wiring between the finisher controller PWA and upper stack tray lift motor correct?

NO

YES

Correct the wiring.

Are the front and rear sides of the upper stack tray leveled?

NO

YES

Level them.

Is the upper stack tray lift motor clock sensor working properly?

NO

YES

Replace the sensor.

Is the stack tray paper height sensor working properly?

NO

YES

Replace the sensor.

Are the upper stack tray upper limit sensor and lower stack tray full sensor working properly?

NO

YES

Replace the sensor or sensor controller PWA.

Does the voltage between the pins J14-1 and -2 on the finisher control PWA 24V when the upper stack tray lift motor starts rotating?

NO

YES

Replace the finisher controller PWA.

Check the wiring between the upper stack tray lift motor and finisher controller PWA. If there is no problem, replace the upper stack tray lift motor.

e-STUDIO160/200/250 TROUBLESHOOTING

4 - 52

December 2002 TOSHIBA TEC

Page 174
Image 174
Toshiba e-Studio250, e-Studio200, e-Studio160 manual CC9