(22) Image dislocation in feeding direction

Feeding direction

Step

Cause/Defect area

Check items

Measures

 

 

 

 

1

Registration roller

Registration roller dirty?

Clean roller surface with alcohol, or replace

 

 

 

roller.

 

 

 

 

2

Pinch roller

Pinch roller spring out of place?

Re-mount or replace spring.

 

 

 

 

3

Paper guide

Paper guide improperly

Re-install paper guide.

 

 

mounted?

 

 

 

 

 

4

Scanner/printer adjust-

Same dislocation on every copy?

Adjust scanner/printer using adjustment

 

ment defect

 

mode.

 

 

 

 

e-STUDIO160/200/250 TROUBLESHOOTING

4 - 80

December 2002 TOSHIBA TEC

Page 202
Image 202