START

: Turn the transfer guide bias ON.

Measure the transfer guide bias at the following two points:

Important:

The settings and conditions of the digital tester to be used for measurement are as

follows:

 

Function switch:

DC

Full scale:

1000V

Remark:

The digital tester to be used should have an input resistance

 

value of 10Mor more.

Measurement value: +375±20V

To measure on the pinch roller:

Frame grounding

Pinch roller

terminal

terminal 01-11-02

CLEAR/STOP

CANCEL

CANCEL

Power OFF

To measure on the paper guide plate:

Frame grounding

Paper guide plate

terminal

01-11-03

terminal

:Turn the transfer guide bias OFF.