EA7
Stack transport jam before stapling
Is there paper remaining on the transport path in the finisher or main unit?
YES
NO
Remove the paper.
Is the connector J9 on the finisher controller PWA disconnected?
Is the harness connecting the finisher controller PWA and stack delivery lever home position sensor broken?
YES
NO
Connect the connector securely. Replace the harness.
Is the stack delivery lever home position sensor working properly?
NO
YES
![]()
1. Connect the connector of the stack delivery lever home position sensor securely. 2. Replace the stack delivery lever home position sensor.
Replace the finisher controller PWA.
EAF
Stapled stack transport jam
Is there paper remaining on the transport path in the finisher or main unit?
YES
NO
Remove the paper.
Is the connector J10 on the finisher controller PWA disconnected?
Is the harness connecting the finisher controller PWA and returning roller home position sensor broken?
YES
NO
Connect the connector securely. Replace the harness.
Is the returning roller home position sensor working properly?
NO
YES
![]()
1. Connect the connector of the returning roller home position sensor securely. 2. Replace the returning roller home position sensor.
Replace the finisher controller PWA.
December 2002 TOSHIBA TEC | 4 - 29 |