CA2
HSYNC abnormality
1.Check if each connector between the laser scanner unit and the main PWA (CN18) is dis- connected.
2.Check if each connector pin is removed or the harness is broken.
3.Check if any conductor pattern on main PWA is open- or
4.Replace the main PWA.
5.Replace the laser scanner unit.
4.1.17Finisher related service call CB2 Delivery motor is abnormal
Rotate the delivery motor by hand. Does it rotates smoothly?
NO
YES
Correct the mechanism.
Is the delivery motor clock sensor working normally?
NO
YES
Replace the sensor.
Is the voltage between J4
NO
YES
Replace the finisher controller PWA.
Is the harness connecting the motor and the controller PWA open- or
YES
NO
Replace the harness.
Replace the motor.
CB5 Staple motor is abnormal
Is the harness connecting the stapler and the finisher controller PWA open- or
YES
NO
Replace the harness.
Is the problem solved by replacing the stapler?
NO
YES
END
Replace the finisher controller PWA.
| 4 - 50 | December 2002 TOSHIBA TEC |