(4)Insert the main recovery PWA into CN10 of the main PWA, with the ROM mounting side facing down.

Main PWA

Main recovery PWA

CN10

05-02-03

Fig 5-2-3

(5)Turn on the power.

Downloading of the main data starts.

The downloading status is displayed on the LCD of the copier as follows:

Data is being downloaded from the ROM on the recovery PWA to the DRAM on the main PWA. The number of displayed squares („) increases.

1

Number of downloaded data 1: Main data

(2: Scanner data)

Data is being stored in the flash ROM from the DRAM. The number of displayed squares („) decreases.

1

Downloading is completed. All dots are blinking.

Note: It takes approx. 5 minutes to download the main data.

December 2002 TOSHIBA TEC

5 - 3

e-STUDIO160/200/250 UPDATING THE FIRMWARE

Page 206
Image 206
Toshiba e-Studio160, e-Studio250, e-Studio200 manual Main PWA Main recovery PWA CN10