ADJUST MODE (05) ITEMS

Process unit adjustment

Code

Factor

Adjustment item (05)

Mode

Default

Acceptable

Refer to

 

 

 

 

 

value

page

 

 

 

 

 

 

 

205

Development

Developer bias DC adjustment

ALL

156

0-255

1-70

 

 

• Increment/decrement by U/D (Up/Down) key

 

(166)

 

 

 

 

Real-time high voltage output

 

 

 

 

 

 

• Developer bias DC ON

 

 

 

 

 

 

 

 

 

 

 

210

Charging

Grid voltage initial value adjustment

ALL

104

0-255

1-70

 

 

• Increment/decrement by U/D key

 

(118)

Guaranteed

 

 

 

Real-time high voltage output (Charge ON)

 

 

value

 

 

 

 

 

*1

0-223

 

 

 

 

 

 

 

 

220

Transfer

Transfer transformer DC output High adjustment

ALL

180

0-255

1-70

 

 

• Increment/decrement by U/D key

 

 

 

 

 

 

Real-time high voltage output (Transfer High ON)

 

 

 

 

 

 

 

 

 

 

 

221

Transfer

Transfer transformer DC output Center adjustment

ALL

142

0-255

1-70

 

 

• Increment/decrement by U/D key

 

(155)

 

 

 

 

Real-time high voltage output (Transfer Center ON)

 

*1

 

 

 

 

 

 

 

 

 

233

Separation

Separation output High adjustment

ALL

67

0-255

1-70

 

 

• Increment/decrement by U/D key

 

 

 

 

 

 

Real-time high voltage output (Separation-High ON)

 

 

 

 

 

 

 

 

 

 

 

234

Separation

Separation output Center adjustment

ALL

49

0-255

1-70

 

 

• Increment/decrement by U/D key

 

 

 

 

 

 

Real-time high voltage output (Separation-Center ON)

 

 

 

 

 

 

 

 

 

 

 

235

Separation

Separation output Low adjustment

ALL

35

0-255

1-70

 

 

• Increment/decrement by U/D key

 

 

 

 

 

 

Real-time high voltage output (Separation-Low ON)

 

 

 

 

 

 

 

 

 

 

 

261

Laser

Laser power 600 DPI Initial value adjustment

ALL

39

0-255

 

 

 

• Increment/decrement by U/D key

 

(53)

 

 

 

 

• No polygon rotation

 

*1

 

 

 

 

Real-time laser output

 

 

 

 

 

 

(Results of automatic laser adjustment)

 

 

 

 

 

 

(Laser ON)

 

 

 

 

 

 

 

 

 

 

 

*1 : The value in parentheses is for the model e-STUDIO200/250 series.

December 2002 TOSHIBA TEC

1 - 9

e-STUDIO160/200/250 ADJUSTMENT ITEMS

Page 17
Image 17
Toshiba e-Studio160, e-Studio250, e-Studio200 manual Adjust Mode 05 Items, Process unit adjustment