(18) Defect of image density/Gray balance

Image density

Feeding direction

Gray balance

Step

Cause/Defect area

Check items

Measures

 

 

 

 

1

Density/Gray balance

Check density/gray balance.

Adjust density.

 

 

 

 

2

Printer section

Check test print image (Code

Go to step 4 if there is any problem on image.

 

 

113).

 

 

 

 

 

3

Scanner

Original glass, mirrors or lens fil-

Clean them.

 

 

ter dirty?

 

 

 

 

 

4

Printed image

Is there any faded image (low den-

Perform troubleshooting for faded image.

 

 

sity)?

 

 

 

 

 

 

 

Is there any fog in background?

Perform troubleshooting for background fog-

 

 

 

ging.

 

 

 

 

 

 

Is there any botch image?

Perform troubleshooting for blotch image.

 

 

 

 

 

 

Is there any transfer defect?

Perform troubleshooting for poor fusing.

 

 

 

 

e-STUDIO160/200/250 TROUBLESHOOTING

4 - 76

December 2002 TOSHIBA TEC

Page 198
Image 198
Toshiba e-Studio250, e-Studio200, e-Studio160 manual Defect of image density/Gray balance