1.8.4 Installing carriage 2

(a) Wire tension adjustment

1.Install wire on carriage 2 by winding up as shown below.

2.Remove the clip jig mounted on scanner drive shaft.

3.Place the spring jig (wire) tension gauge on wire holder and scanner drive shaft and then screw it.

Wire

Wire

Wire

Scanner drive shaft

061

Fig. 1-8-15

Wire holder

Screw

Scanner drive shaft

Spring jig (Wire)

Fig. 1-8-16

062-1

4.Remove the spring jig (wire) gauge and loosen 2 screws retaining slide plate.

5.To take up the winding slack of wire, move car- riage 2 back and forth once (to the center of scanner) and securely hold the carriage to the left side frame.

6.Tighten 2 screws to secure slide plate.

Slide plate

Screw

062-2

Fig. 1-8-17

Slide plate

Carriage 2

Screw

062-3

Fig. 1-8-18

December 2002 TOSHIBA TEC

1 - 79