41

Right/Left air direction adjustment

To change the air outlet direction to the right or left side, set the vertical louver located behind the horizontal louver to the desired direction.

INFORMATION

• If cooling operation is performed with a donwards discharge, dew may form on the surface of the cabinet or the horizontal louver resulting in possible dripping.

If heating operation is performed with a horizontal discharge, the room temperature may not be equal i.e. there may be a large variance between one side of the room with the other.

High Wall Type

Adjustment of air Flow direction Upwards/Downwards

[In Cooling operation]

In cooling operation, use the horizontal louver with a horizontal set point so that the cold air diffuses the whole room.

[In Heating operation]

In heating operation, use the horizontal louver with a downwards set point so that the hot air blows towards the floor.

REQUIREMENT

If cooling operation is performed with the louver set at a down- wards position, dew may form on the surface of the cabinet or the horizontal louver resulting in possible dripping.

If heating operation is performed with the louver set in a horizon- tal position, the room temperature may not be equal i.e. there may be a large variance between one side of the room with the other.

Do not move the horizontal louver directly with your hands; otherwise a fault maybe caused. Select the direction of the

horizontal louver using the SWING/FIX button on the remote controller. The horizontal louver will not stop immediately even if the switch is pushed. Note pushing the switch again when the required louver direction has been reached will stop the louver.

Adjustment of air Flow direction rightwards/leftwards

To change the air outlet direction to the right or left side, set the vertical louver located behind the horizontal louver to the desired direction.

Setup of air direction and swinging

1H series: Refer to the description of

“2-way Air Discharge Cassette Type”.

2H series: Refer to the description of “Under Ceiling Type, 1-way Air Discharge Cassette Type (2SH Series)”.

Floor Standing Cabinet Type

[In Cooling operation]

In cooling operation, set the air outlet louver with a horizontal set point so that the cold air diffuses the whole room.

[In Heating operation]

In heating operation, set the air outlet louver with a down- wards set point so that the hot air blows towards the floor.

How to change the air outlet port

Change the air outlet port using the following procedure.

1 Remove the two fixing screws on the air outlet port.

(The fixing screws are reused.)

2 Remove the discharge port, by pushing up on the rear side, to a point where you can remove it from the rear clip.

3 Lift the air outlet port upwards and remove it.

4 Reverse the air outlet port and attach it to the main unit.

Pay attention so that four claw hooks (two at rear and two at the lower sides) are hooked on the mounting position.

5 Be sure to tighten the air outlet port with the removed fixing screws so that the air outlet port does not come off.