TMP92CZ26A

92CZ26A-426

(b) Interrupt transfer type
Interrupt transfer type use transaction format same with transmission bulk
transfer.
When transmission by using toggle bit, hardware setting and answer in UDC
are same with transmission bulk transfer. Interrupt transfer can be transferred
without using toggle bit. In this case, if ACK handshake from host is not received,
toggle bit is renewed, and finish normally. UDC clears FIFO for next transfer.
(b-1) Interrupt transmitt ing mode (Toggle mode)
UDC operation is sam e with bulk transmission mode. Please refer to section
(a).
(b-2) Interrupt transmission mode (Not toggle mode)
This is same bulk transmission mode basically. However, if ACK handsha ke
from host is not received, transaction is different.
After transmit data packe t,
When ACK handshake from host is received,
Clear FIFO.
Clear DATASET register.
Renew toggle bit and prepare for next .
Set STATUS to READY.
UDC finishes normally by above transaction. FIFO can be received next data.
If it is time out without receiving ACK from host,
Clear FIFO.
Clear DATASET register.
Renew toggle bit and prepare for next .
Set STATUS to TX_ERR.
Execute above setting. This setting is same with except STATUS.