TMP92CZ26A

92CZ26A-364

(4) Stop condition generation
When SBISR<BB> = “1”, the sequence for generating a stop condition start by
writing “1” to SBICR2<MST, TRX, PIN> and “0” to SBICR2<BB>. Do not modify the
contents of SBICR2<MST, TRX, PIN, BB> until a stop condition has been generated
on the bus. When the bus’s SCL line has been pulled Low by another device, the
TMP92CZ26A generates a stop condition when the other device has released the SCL
line and SDA pin rising.
7 6 5 4 3 2 1 0
SBICR2 1 1 0 1 1 0 0 0 Generate stop condition.
Figure 3.15.18 Stop condition generation (Single master)
Figure 3.15.19 Stop condition generation (Multi master)
SCL pin
SDA Pin
<PIN>
<BB> (Read)
Stop condition
“1” <MST>
“1” <TRX>
“0” <BB>
“1” <PIN>
Internal SCL
Internal SCL
SDA Pin
<PIN>
<BB> (Read)
Stop condition
“1” <MST>
“1” <TRX>
“0” <BB>
“1” <PIN>
SCL Pin
The case of pulled low
by another device