TMP92CZ26A

92CZ26A-437

5. Below is transaction when SOF token from host is received.
Change the packet As FIFO from X Condition to Y Condition. And
clear data.
Change the packet B from Y Condition to X Condition.
Set frame number to frame register.
Assert SOF and inform that fram e is incremented to external.
DATASET register clears packet A bit and it sets packet B bit
arrangement loading in presen t frame.
Set STATUS to READY.
UDC finishes normally by above transaction.
Packet As FIFO can be received next data.
In renewed frame, Packet As FIFO interchange packet B’s FIFO, and
transaction is used same flow.
If SOF token is not received by error and so on, this data is lost because of
frame is not renewed. Nothing problem in receiving PID and if frame data is
received with CRC err or, USB sets LOST to STATUS on FRAM E register, and
frame number is not renewed. However, in this case, SOF is asserted and
FIFO condition is renewed. If SOF token is received without transmit and
transfer Isochronous in frame, UDC clears FIFO (X Condition) and sets
STATUS to FULL.