TMP92CZ26A

92CZ26A-604

AD Conversion Result Co mpare Criterion Register 0 Low
7 6 5 4 3 2 1 0
bit Symbol ADR21 ADR20
Read/Write R/W
After reset 0 0
Function Store Lower 2 bits of an
AD conversion result
compare criterion
AD Conversion Result Co mpare Criterion Register 0 High
7 6 5 4 3 2 1 0
bit Symbol ADR29 ADR28 ADR27 ADR26 ADR25 ADR24 ADR23 ADR22
Read/Write R/W
After reset 0 0 0 0 0 0 0 0
Function Store Upper 8 bits of an AD conversion result compare criterion
AD Conversion Result Co mpare Criterion Register 1 Low
7 6 5 4 3 2 1 0
bit Symbol ADR21 ADR20
Read/Write R/W
After reset 0 0
Function Store Lower 2 bits of an
AD conversion result
compare criterion
AD Conversion Result Co mpare Criterion Register 1 High
7 6 5 4 3 2 1 0
bit Symbol ADR29 ADR28 ADR27 ADR26 ADR25 ADR24 ADR23 ADR22
Read/Write R/W
After reset 0 0 0 0 0 0 0 0
Function Store Upper 8 bits of an AD conversion result compare criterion
Note: Disable the AD monitor function (ADMOD4<CMEN> = “0”) before attempting to set or modify
the value of these registers.
Figure 3.23.10 AD Conversion Registers
A
DCM0REGL
(12B4H)
A
DCM0REGH
(12B5H)
A
DCM1REGL
(12B6H)
A
DCM1REGH
(12B7H)