(c) Control transfer type
Control transfer type is configured in below thre e stages.
Setup stage
Data stage
Status stage
Data stage is skipped sometimes. Each stage is configured in one or plural
transaction. UDC executes each transaction while managing of three stages in
hardware. Control transfer type has below 3 type by whether there is data stage
or not, or direction.
Control read transfer typ e
Control write transfer ty pe
Control write transfer type (Not data stag e)
3-transfer sequences are shown in Figure 3.16.10, Figure 3.16.11 and Figure
3.16.12.
UDC answers automatica lly about standard request in hard ware. Class request,
vendor reques t have to intervening CPU on controlling UDC.
Below is control f low in UDC and control flow in intervening CPU.
(c-1) Setup stag e
Setup stage is same with transmission bulk transac tio n except case of token ID
become to SETUP.
However, co ntrol flow in UDC d if fer it.
Token: SETUP
Data: DATA 0
Handshake: ACK
Control flow
Below is control fl ow in UDC when SETUP token is received.
1. SETUP token pack et is received and addr ess, endpoint number and error
are confirmed. And it checks whether applicable endpoint is the control
transfer mode.
2. STATUS register state is confirmed.
State return to IDLE only it is INVALID state.
In bulk transfer mode, receivin g data is enab led by STATUS registers value
and FIFO condition. However, in SETUP stage, STATUS is returned to
READY and accessing from CPU to FIFO is prohibited always, and internal
FIFO of endpoint 0 is cleared. And it prepares for following dataphase.
If CPU accesses Setup Received registers in UDC, it recognizes as Device
request is received, and accessing from CPU to EP0 is enab led.
There is this function for receiving it if new request is received in during
present device request is not finishing normally.