TMP92CZ26A

92CZ26A-661

4.3.9 LCD Controller

Variable
Parameter Symbol
Min Max
80 MHz
(n=0)
60 MHz
(n=0) Unit
LCP0 clock period tCW 2T(n+1) 25 33.3
LCP0 high width
(Include phase inversion) tCWH T(n+1) 5 7.5 11.6
LCP0 low width
(Include phase inversion) tCWL T(n+1) 5 7.5 11.6
Data valid LCP0 falling
(Include phase inversion) tDSU T(n+1) 7.5 5 9.1
LCP0 falling Data hold
(Include phase inversion) tDHD T(n+1) 7.5 5 9.1
Signal delay from LCP0 basic
changing point
(Include phase inversion)
tGDL -20 20
20 20
ns
AC measuring condition
C
L = 50 pF (LCP0 only CL = 30 pF)
Note: The “n” in “Variable” show value that is set to LCDMODE0<SCPW1:0>.
Example: If LCDMODE0<SCPW1:0> = “01”, n=1, tRWP= 2T(n+1) = 2T
LCP0 tCWH tCWL
tCW
LD0~LD23
tDHD
tDSU
LD0~LD23 out
LVSYNC
LHSYNC
FR
LLOAD
LGOE0
LGOE1
LGOE2
tGDL
LDINV LDINV