Specifying input parameters

VOLUME KCODE

Specifies which double-byte character code translation table the system will use to interpret the input data.

Syntax VOLUME KCODE = {keyword id }

Options

Table 2-66. VOLUME KCODE parameter options and definitions

Option

Definition

 

 

 

 

keyword

Specifies a specific, standard, system defined double-byte code translation

 

table. The available options are:

 

• IBM: IBM Nihongo character set (Kanji double-byte character sets)

 

• IBMCHN: IBM 5550 code translation table

 

• JEF: Fujitsu JEF Kanji double-byte character set

 

• KEIS: Hitachi KEIS Kanji double-byte character set

 

• UCS2: ISO/IEC 10646 UCS2 character set

 

• USER: Refers to the single unlabeled KCODE command defined within

 

 

the JDL or JDE.

 

 

id

Specifies an identifier label that was used in a previously defined KCODE

 

command to refer to a specific, user-defined code translation table. The id label

 

is required when multiple KCODE commands are contained within the JDL.

 

 

 

Default

 

No default

 

 

VOLUME LABEL

 

 

 

 

 

Specifies the type of label on the input tape.

Syntax VOLUME LABEL = label type

Options

Table 2-67. VOLUME LABEL parameter options and definitions

Option

Definition

 

 

 

 

label-type

Specifies the type of label that the tape contains. The following types

 

may be specified:

 

• COBOL (Honeywell 2000 COBOL tape with 120-byte labels)

 

• NONE (the input tape is unlabeled)

 

ANSI/XEROX ANSI

 

• SPR (Honeywell 2000 System Print Tape)

 

STANDARD

 

• UNDEF (Input tape label is not defined)

 

 

 

Using LCDS Print Description Language

2-63

Page 171
Image 171
Xerox 701P21091 manual Options 66. Volume Kcode parameter options and definitions, SPR Honeywell 2000 System Print Tape