Xerox 701P21091 manual Options 34. Rpage Test parameter options and definitions, Default TOP

Models: 701P21091

1 498
Download 498 pages 22.54 Kb
Page 225
Image 225

Using logical processing

RPAGE TEST

Defines the test expression for detection of an RPAGE record that will cause the logical page to be repositioned on a physical page.

Syntax RPAGE TEST = testexp

Options

Table 3-34. RPAGE TEST parameter options and definitions

Option

Definition

 

 

 

 

testexp

test expression.

 

Specifies the criteria test that, if met, will reposition the logical page.

 

The logical page on which this record normally appears is called the “current

 

logical page.”

 

(Refer to “Coding a test expression,” earlier in this chapter, for the format and

 

syntax of a test expression.)

 

 

 

Default

 

No default

 

 

RPAGE WHEN

 

 

 

 

 

Defines the portion of the current logical page that will be

 

 

positioned to the first logical page of a new location.

Syntax RPAGE WHEN = {TOP BOTTOM NOW}

Options

Table 3-35. RPAGE WHEN parameter options and definitions

Option

Definition

 

 

 

 

BOTTOM

The logical page following the current logical page is repositioned.

 

 

NOW

The current record is repositioned. This record prints at TOF. Any spacing or

 

skipping defined to occur before printing the current record is ignored.

 

 

TOP

The current logical page is repositioned.

 

 

Default TOP

Using LCDS Print Description Language