Xerox 701P21091 manual Options 15. CME Constant parameter options and definitions, CME Font

Models: 701P21091

1 498
Download 498 pages 22.54 Kb
Page 253
Image 253

Specifying print format parameters

CME CONSTANT

Specifies a character string to print.

Syntax [ac:] CME CONSTANT = sc

Options

Table 4-15. CME CONSTANT parameter options and definitions

 

Option

 

Definition

 

 

 

 

 

 

 

 

 

sc

 

string constant.

 

 

 

Represents the character string to be printed. The width of the copy

 

 

 

modification rectangle is determined by the number of characters

 

 

 

specified by sc.

 

 

 

More than one string constant is allowed.

 

 

 

 

Default

No default

CME CONSTANT

The CONSTANT parameter of the CME has no default and must

parameter: point

be specified, unless all that is required is a font change in the

to note

variable data.

 

 

CME FONT

 

 

 

 

 

 

Specifies a value to be used as an index into the font list (as

 

 

specified by the PDE command or a DJDE). The selected font is

 

 

used when imaging the input data or CME data. (A PDE

 

 

command is selected by the FORMAT parameter of the OUTPUT

 

 

command.)

Syntax

[ac:] CME FONT = value

Option

Table 4-16. CME FONT parameter option and definition

Option

Definition

 

 

 

 

value

May range from 1 to n, where n is the number of different fonts specified

 

by the FONTS parameter of the PDE command.

 

A value of 1 specifies the first font in the PDE FONTS parameter, 2 the

 

second, and so forth.

 

The default for a value is the current font (specified with the last FONT

 

parameter; initially the value is 1).

 

 

Using LCDS Print Description Language

4-13

Page 253
Image 253
Xerox 701P21091 manual Options 15. CME Constant parameter options and definitions, CME Font