CNX System Administrator Guide

Safety warnings

General warnings

The following safety warnings apply:

Mechanical hazards and electrical shock hazards are possible if you remove one or more of the modules. There are no operator-serviceable modules. Only qualified personnel should service this equipment.

This equipment must be connected to a protective ground according to the instructions in this manual. Improper grounding may result in electrical shock.

This equipment does not provide safety isolation between any port that is connected to a digital network termination point or any port to which terminal equipment is connected.

The wall circuit breaker provides the main protection for this equipment.

Ensure that rack installation does not result in airflow blockage to power supply vents or chassis vents.

Before installing the Aastra CNX rackmount version, ensure that the rack is sturdy and well-secured.

Lithium battery caution

CAUTION: Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer’s instructions.

ATTENTION: Il y a danger d’explosion s’il y a remplacement incorrect de la batterie. Remplacer uniquement avec une batterie du même type ou d’un type recommandé par le constructeur. Mettre au rebut les batteries usagées conformément aux instructions du fabricant.

Compliances

The Aastra CNX is in compliance with regulations as follows:

Environmental

32-104° F (0-40° C)

Humidity 10-85% non-condensing

400 BTUs/hour

28 dBA maximum acoustic noise

Safety Certifications

cUL 950, NTRL/UL 1950, TUV EN 60 950

Telecom Approvals

FCC Part 68, Industry Canada, CTR4

EMI/RF

FCC Part 15 Class A, EN55022 Class A (CISPR), EN55024