Configuring the Aastra CNX
Procedures
| Step | Action | 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 10 | Configure the attributes as required. | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | Attribute | Default | Valid Values/Description | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | Framing Type | T1 FRAMING | T1 FRAMING | 
 | 
| 
 | 
 | 
 | 
 | E1 FRAMING | 
 | 
| 
 | 
 | Clocking | PORT 1 CLOCK | INTERNAL CLOCK | 
 | 
| 
 | 
 | 
 | 
 | PORT 1 CLOCK | 
 | 
| 
 | 
 | 
 | 
 | PORT 2 CLOCK | 
 | 
| 
 | 
 | 
 | 
 | PORT 3CLOCK | 
 | 
| 
 | 
 | 
 | 
 | PORT 4CLOCK | 
 | 
| 
 | 
 | 
 | 
 | INTERNAL CLOCK - Uses the internal Aastra CNX | 
 | 
| 
 | 
 | 
 | 
 | clock for synchronization on TDM links. | 
 | 
| 
 | 
 | 
 | 
 | PORT 1 thru PORT 4 CLOCK - Uses the external | 
 | 
| 
 | 
 | 
 | 
 | clocking on port 1 thru port 4, respectively, for | 
 | 
| 
 | 
 | 
 | 
 | synchronization on TDM links. | 
 | 
| 
 | 
 | Switch Type | For T1 Framing: | For T1 Framing: | 
 | 
| 
 | 
 | 
 | DMS 100 | DMS 100 | 
 | 
| 
 | 
 | 
 | 
 | 5ESS | 
 | 
| 
 | 
 | 
 | For E1 Framing: | NI2 | 
 | 
| 
 | 
 | 
 | ETSI | FXO Loop Start | 
 | 
| 
 | 
 | 
 | 
 | FXO Ground Start | 
 | 
| 
 | 
 | 
 | 
 | FXS Loop Start | 
 | 
| 
 | 
 | 
 | 
 | FXS Ground Start | 
 | 
| 
 | 
 | 
 | 
 | E&M | 
 | 
| 
 | 
 | 
 | 
 | For E1 Framing: | 
 | 
| 
 | 
 | 
 | 
 | ETSI | 
 | 
| 
 | 
 | 
 | 
 | Description: Specifies the switch type for the ISDN | 
 | 
| 
 | 
 | 
 | 
 | PRI connection. | 
 | 
| 
 | 
 | 
 | 
 | Descriptions of T1 Switch Types: | 
 | 
| 
 | 
 | 
 | 
 | DMS 100 - Northern Telecom Inc.  | 
 | 
| 
 | 
 | 
 | 
 | 5ESS - Lucent 5ESS | 
 | 
| 
 | 
 | 
 | 
 | NI2 - North American National ISDN 2  | 
 | 
| 
 | 
 | 
 | 
 | switch | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 