CNX System Administrator Guide
Record type | Found in | Found in | Aastra CNX generates the record in a log.... | ||
cdrlog files | confcdrlog files | ||||
|
|
|
| ||
CALL_END |
| - | when a user disconnects a call or is disconnected | ||
|
|
| from the Aastra CNX using call types of TDM, SIP, | ||
(Call End Record) |
|
| or H.323. A CALL_END record includes: | ||
|
|
| • | Caller ID | (integer) |
|
|
| • | Conference ID | (interger) |
|
|
| • | Call type | (TDM/SIP/H323) |
|
|
| • | Caller | (SIP/H323 address of the |
|
|
|
|
| caller or the caller’s phone |
|
|
|
|
| number) |
|
|
| • | Reason | (Disconnect cause)* |
|
|
| • | Duration in minutes |
*Disconnect causes could be any of the following:
Disconnect | Description | |
cause | ||
| ||
|
| |
NORMAL | Normal call clearing (for | |
| example, a | |
| conference). | |
|
| |
SHUTDOWN | System was shutting down. | |
|
| |
NO_RESOURCES | All 30/60 ports in use. | |
|
| |
LOGIN_FAILED | Incorrect pin entered. This | |
| cause may log even if a user | |
| enters the wrong pin once, and | |
| then hangs up. | |
|
| |
NOT_STARTED | Attempted to log into a | |
| conference that has not yet | |
| started. | |
|
| |
NO_PORTS | All the reserved ports for the | |
| conference are in use. | |
|
| |
EJECTED | The moderator ejected the user | |
| off of the bridge. | |
|
| |
CONF_OVER | User is ejected from the | |
| conference because the | |
| conference time was up. | |
|
| |
INTERNAL_ERROR | An error condition on the CNX | |
| occurred; check the logs for | |
| error messages. | |
|
| |
UNKNOWN | Unknown error | |
|
|