Manual background

Configuring the Aastra CNX

Procedures

Step

Action

 

 

 

 

 

 

 

 

 

13

Configure the attributes as required.

 

 

 

 

 

 

 

 

 

 

Attribute

Default

Valid Values/Description

 

 

 

Windows

DISABLE

ENABLE

 

 

 

Authentication

 

DISABLE

 

 

 

 

 

Description: Specifies whether or not to authenticate

 

 

 

 

 

a user against a Windows server.

 

 

 

Domain Username

None

Description: Specifies the username of a Windows

 

 

 

 

 

domain administrator.

 

 

 

 

 

Note: This is used once to register the Aastra CNX

 

 

 

 

 

with the Windows domain.

 

 

 

Domain Password

None

Description: Specifies the password of a Windows

 

 

 

 

 

domain administrator.

 

 

 

 

 

Note: This is used once to register the Aastra CNX

 

 

 

 

 

with the Windows domain.

 

 

 

Domain

None

Description: Specifies the Windows domain that the

 

 

 

 

 

Aastra CNX uses. This is the default domain for users

 

 

 

 

 

who do not specify a domain and for users who do not

 

 

 

 

 

have accounts on the Aastra CNX.

 

 

 

Primary Domain

0.0.0.0

Description: Specifies the hostname or IP address of

 

 

 

Controller

 

the server that the Aastra CNX uses to join the

 

 

 

 

 

domain.

 

 

 

 

 

Note: The Primary Domain Controller (PDC) is

 

 

 

 

 

considered the “master” DC on the network for a

 

 

 

 

 

particular workgroup/domain.

 

 

 

Password Server

0.0.0.0

Description: Specifies the hostname or IP address of

 

 

 

 

 

the server that the Aastra CNX uses to authenticate

 

 

 

 

 

users.

 

 

 

 

 

Note: In most cases, this is also the PDC or a Backup

 

 

 

 

 

Domain Controller (BDC).

 

 

 

Wins Server

0.0.0.0

Description: Specifies the hostname or IP address of

 

 

 

 

 

the server that the Aastra CNX uses to resolve

 

 

 

 

 

Windows names.

 

 

 

 

 

Note: WINS is a Microsoft Windows NT or Windows

 

 

 

 

 

2000 service that dynamically registers names of

 

 

 

 

 

computers on the network. In most cases, the WINS

 

 

 

 

 

server is the PDC or BDC.

 

 

 

 

 

 

 

 

 

 

 

 

 

ATP-CNX-040-01 Rel. 1.3, Doc. Rev. 01.07