Command Set

5017H Analog Input

 

 

$aaSiCjB

$aaSiCjB

Example

command: $35S3C1B(cr)

 

response: !350b00(cr)

Channel 1 of the ADAM-5017H module in slot 3 of the ADAM-5000 system at address 35h responds with an input range 0-20 mA, engineering unit data format.

6-62

ADAM-5000

Page 184
Image 184
Advantech RS-485 user manual Command Set 5017H Analog Input, Example Command $35S3C1Bcr Response !350b00cr