Command Set | 5017H Analog Input |
|
|
#aaSiCj | #aaSiCj |
If (data)=” “, it means the channel is invalid.
(dddd)is the input value in two’s complement format of the specified channel of the specified module. If (dddd)=” “, it means the channel is invalid.
(cr) is the terminating character, carriage return (0Dh).
Example command: #35S3C2(cr)
response: +9.750 (cr)
The command requests the
The analog input module responds that the input value of channel 2 is +9.750.