Allied Telesis AT-9900 Create switch trunk, Enable switch port vlan, Set lacp, Set switch port

Models: AT-9900 AT-8700XL AT-9800 AT-8600 RAPIER I AT-8800 AT-8900 X900-48FE

1 232
Download 232 pages 5.78 Kb
Page 28
Image 28

28

Switching Enhancements

Release Note

To view details about disabled ports for VLANs, use one of the commands:

show vlan[={vlan-name1..4094all}]

show vlan[=all]

Re-enabling a port When a port is disabled, either completely or for a specific VLAN, it remains disabled until it is manually re-enabled in any of the following ways:

with SNMP

as the result of a reboot

by specifying a thrash timeout value along with the thrash action

via the CLI

If the vlandisable thrash action has been applied, to re-enable one or more ports from VLANs to which they belong, use the command:

enable switch port={port-listall} vlan[={vlan-name1..4094all}]

If either the portdisable or linkdown thrash action has been applied, to re-enable one or more ports, use the command:

If the learndisable thrash action has been applied, the port is automatically re-enabled when the defined timeout expires. You cannot manually re-enable the port.

Port Types Limiting rapid MAC movement is supported on all port types. It is also supported on trunked ports.

Command Changes

The following table summarises the new and modified commands:

Command

Change

 

 

create switch trunk

New thrashaction parameter.

 

New thrashtimeout parameter.

 

 

enable switch port vlan

New command.

 

 

enable switch port vlan

New command.

 

 

set lacp

New thrashaction parameter.

 

New thrashtimeout parameter.

 

 

set switch port

New thrashaction parameter.

 

New thrashtimeout parameter.

 

New vlanstatustrap parameter.

 

 

set switch thrashlimit

New command.

 

 

set switch trunk

New thrashaction parameter.

 

New thrashtimeout parameter.

 

 

show lacp

New address learn thrash action parameter.

 

New address learn thrash timeout parameter.

 

 

show switch port

New address learn thrash status parameter.

 

New address learn thrash action parameter.

 

New address learn thrash timeout parameter.

 

New vlan status trap parameter.

 

 

Software Version 2.8.1 C613-10477-00 REV B