Instrument Overview

Graphical User Interface Overview

Table 3-6.Spectral Analysis Graticule Legend

Index Description

Status Indicator: This indicator (asterisk) is displayed when the current instrument setup does not correspond to the one which was applied when a trace is displayed. This happens when:

1The instrument setup is modified when the Sweep mode is set to Single and a new sweep has not yet been triggered.

The instrument setup is modified in the middle of a measurement. The measurement is re-started with the new setup and this indicator is shown until the entire trace is re-written.

2Y-axis Scale: The Y-axis scale is labeled every other major grid line.

3Sweep Status: Displays the sweep status of Triggered and Single sweep modes.

Trace Information: Trace information is displayed in the following format (the current active trace has the text underlined):

4 to 8

Trc<n> <Trace Mode>

<Detector Mode>

<Trace Math>

Where:

n:Trace Number (1 to 5)

Trace Mode: Trace Mode (Clear Write, Max Hold, Min Hold, Average, View, or Off)

Detector: Detector Type (Auto, Normal, Maximum, Minimum, Sample, Average, or RMS)

Trace Math: Trace Math indicator (available when Trace Mode: Average is selected)

9

Sweep Mode: This field is used to display the sweep modes of Swept, FFT (Fast Fourier Transform), or

FFT-WB (Wideband).

 

10

Start Frequency: Indicates the start frequency of the sweep.

 

 

11

Frequency/Division: This field indicates the horizontal scaling per division.

 

 

12

Center Frequency: Indicates the center frequency of the sweep. If a frequency offset is set, OFFSET is

also displayed.

 

13

Span Frequency: Indicates the total span of the frequency sweep.

 

 

14

Stop Frequency: Indicates the stop frequency of the sweep.

 

 

15

Trace Display: Up to five traces can be displayed using the following colors: Trace 1--Yellow, Trace 2--

Green, Trace 3--Cyan, Trace 4--Magenta, Trace 5--Red

 

16

Marker Display: Markers are annotated with the absolute power level next to the marker location.

17

Marker Display: Markers are annotated with the absolute power level next to the marker location.

 

 

18

Display Line: A display line may be displayed at any desired level.

 

 

 

Active Marker Field: The active marker number, frequency, and amplitude values are displayed in this

19

field. The trace that has received the marker is indicated in brackets. If the Marker is a Delta Marker, the

delta symbol (D) precedes the Mkr number and the values displayed are relative to the reference

 

 

marker.

 

 

20

Reference Marker Field: The reference marker number, frequency, and amplitude values are displayed

in this field. The displayed values are absolute in magnitude.

 

 

 

21

Bandwidth Setup: The bandwidth setup field displays the current Resolution Bandwidth, Video

Bandwidth, and Sweep Time settings. If the settings are manually entered, an asterisk is displayed.

 

22

Amplitude Setup: The amplitude setup field displays the current attenuation level, reference level, and

reference level offset. If the attenuation is set manually, an asterisk is displayed.

 

MS278XB OM

3-27

Page 79
Image 79
Anritsu Series MS278XB operation manual Index Description