Tools
Probing disk drives
This test checks all disk drives.
Symptom - The internal disk drives are reporting errors.
Solution - To check the status of the disk drives:
1.Enter:
/usr/sbin/shutdown -y -i0 -g0
This shuts down the system.
2.At the ok prompt, enter the following commands: setenv
reset-all
The system resets.
3.Enter:
The program displays a message that is similar to the following:
LiD HA LUN | |||||
0 | 0 | 0 | 21000004cf72f08f | SEAGATE | ST373405FSUN3660438 |
1 | 1 | 0 | 21000004cf721553 | SEAGATE | ST373405FSUN3660438 |
2 | 2 | 0 | 21000004cf7213ea | SEAGATE | ST373405FSUN3660438 |
6 | 6 | 0 | 508002000016b5b1 | SUNW | SUNWGS INT FCBPL9224 |
3 | 3 | 0 | 21000004cf72114b | SEAGATE | ST373405FSUN3660438 |
4 | 4 | 0 | 21000004cf7211ae | SEAGATE | ST373405FSUN3660438 |
5 | 5 | 0 | 21000004cf7214a3 | SEAGATE | ST373405FSUN3660438 |
|
|
|
|
|
|
Note:
The actual response depends on the number of disk drives that are installed in the system. This example shows six disk drives and the disk drive backplane.
4.Fix any obvious errors, such as disconnected backplane cables or disk drives not completely inserted.
Issue 2.0 June 2004 169