Maintaining disk drives
23. Enter the following commands: setenv
The system reboots to the ok prompt.
24. Enter:
probe-scsi
This verifies that the system recognizes all of the disk devices, including the newly installed ones. A message that is similar to the following example is displayed:
LiD HA LUN | |||||
0 | 0 | 0 | 21000004cf72f08f | SEAGATE | ST373405FSUN3660438 |
1 | 1 | 0 | 21000004cf721553 | SEAGATE | ST373405FSUN3660438 |
6 | 6 | 0 | 508002000016b5b1 | SUNW | SUNWGS INT FCBPL9224 |
3 | 3 | 0 | 21000004cf72114b | SEAGATE | ST373405FSUN3660438 |
4 | 4 | 0 | 21000004cf7211ae | SEAGATE | ST373405FSUN3660438 |
|
|
|
|
|
|
The devices listed depends on the number of disks that are installed in the system.
25. Enter the following commands:
!
CAUTION:
If you fail to enter these commands, any reboots that you do in the future will stop at the boot prompt instead of proceeding through the normal
setenv auto-boot? true
boot -r
The system reboots.
26.Log in as root.
27.Continue with Setting up replacement disk drives on page 112.
Issue 2.0 June 2004 111