14-10
User Guide for Resource Manager Essentials 4.1
OL-11714-01
Chapter 14 Enabling and Tracking Syslogs Using Syslog Analyzer and Collector
Using Syslog Analyzer

Timezone List Used By Syslog Collector

The timezone of the system where the Syslog Collector is running. In the Syslog Collector Properties
file, you must enter the correct abbreviation for the timezone. See Understanding the Syslog Collector
Properties File.
For the correct Timezone abbreviation, see the Timezone file in the following location:
$NMSROOT/MDC/tomcat/webapps/rme/WEB-INF/classes/com/cisco/nm/rmeng/fcss/data/TimeZone.l
st
Each entry in the TimeZone.lst file represents a timezone abbreviation, and its offset from GMT. Each
offset here is 10 multiplied by the actual offset. For example, the actual offset for IST is 5.5 hours, and
the corresponding entry here is 55.
You must use the same method while modifying it.
The following is the timezone list used by SyslogCollector:

Using Syslog Analyzer

The following is the workflow for Syslog Analyzer:
Step 1 Configure devices (see Configuring Devices to Send Syslogs).
Step 2 Configure the Common Syslog Collector which is installed during the RME installation, or install
another Remote Syslog Collector on another machine (see the Installation and Setup Guide for Resource
Manager Essentials).
Step 3 Perform various tasks such as defining and managing filters, automated actions, setting back-up policy,
setting the purge policy, performing a forced purge, defining custom reports templates, specifying the
path for the Syslog message file, etc.
Time Zone List Used by Syslog Collector
ACT=95 ADT=30 AET=100 AEST=100 AGT=-30
AHST=-100 ART=20 AST=-90 AT=-20 BET=-30
BST=10 BT=30 CAT=10 CCT=80 CDT=-50
CEST=20 CET=10 CNT=-35 CST=-60 CTT=80
EADT=-110 EAST=100 EAT=30 ECT=10 EDT=-40
EET=20 EST=-50 FST=-20 FWT=10 GMT=0
GST=100 HDT=90 HST=-100 IDLE=120 IDLW=-120
IET=-50 IST=55 JST=90 MDT=-60 MEST=-20
MESZ=-20 MET=10 MEWT=10 MIT=-110 MST=-70
MYT=80 NET=40 NST=120 NT=-110 NZDT=130
NZST=120 NZT=120 PDT=-70 PLT=50 PNT=-70
PRT=-40 PST=-80 SST=110 SWT=10 UTC=0
VST=70 WA D T = - 8 0 WA S T = 7 0 WAT = - 1 0 YDT=-80
YST=-90 ZP4=40 ZP5=50 ZP6=50